MR-compatible Small Animal Capnograph Module for Rodents

The microCapStar Capnometer provides accurate end-tidal or continuous measurement of expired CO2 in animals as small as mice.  It features very low sample flow requirements, rapid response time and long term stability.  The Capnometer control and measuring module is positioned outside the magnet room and connected to the animal in the magnet bore using long pneumatic tubes.   A Capnometer Interface Module sends data from the capnometer to a PC for recording and display.   The microCapStar Capnometer can be used with the Model 1025 and 1030 MR-compatible Monitoring and Gating Systems as well as with the Model 1025L and 1025T Monitoring and Gating Systems for use in other imaging environments and in the laboratory.

Request Quote
Category:

Description

The microCapStar Capnometer provides accurate end-tidal or continuous measurement of expired CO2 in animals as small as mice.  It features very low sample flow requirements, rapid response time and long term stability.  The Capnometer control and measuring module is positioned outside the magnet room and connected to the animal in the magnet bore using long pneumatic tubes.   A Capnometer Interface Module sends data from the capnometer to a PC for recording and display.   The microCapStar Capnometer can be used with the Model 1025 and 1030 MR-compatible Monitoring and Gating Systems as well as with the Model 1025L and 1025T Monitoring and Gating Systems for use in other imaging environments and in the laboratory.

         
  • Mice and larger animals
  • Low sample flow
  • Ventilator compatible
  • Easy to use
  • Accurate
  • Reliable
  The CO2  waveform, respiration rate, end-tidal CO2 and absolute pressure are displayedand recorded along with all other available physiological monitoring parameters by a PC running SA Instruments’ PC-SAM software.  The CO2 waveform and end-tidal CO2 can be displayed in either mmHg or percent.   The heart of the microCapStar is a miniature, infrared CO2 sensor with a temperature controlled sample cell.  The heated sample cell prevents water condensation even during long measurement sessions.  Low sample flow and rapid response is achieved with a carrier gas system where the high flow carrier gas quickly brings the low flow sample to the sample cell.  Digitally controlled flow management automatically maintains a precise ratio of carrier flow to sample flow which is essential for accurate measurements.   Adjustable alarms provide a warning when end-tidal CO2 is out of a user adjustable preset range.  Built in diagnostics warn of plugged sample tubing or other fault conditions.  Calibration is performed with a single calibration gas and room air.

Download the capnograph Brochure